This information is for educational purposes only. It is not intended as medical advice. Always consult a qualified healthcare professional.
OTC
Choline C 11
4-33.1mCi/ML, Injectable
INN: CHOLINE C-11
Data updated: 2026-05-02
Available in:
🇩🇪🇬🇧🇫🇷
Form
INJECTABLE
Dosage
4-33.1mCi/ML
Route
INTRAVENOUS
Storage
16.2 Storage and Handling Store Choline C 11 Injection at 25°C (77°F); excursions permitted to 15 – 30°C (59 – 86°F) (see USP Controlled Room Temperature). Use the solution within 120 minutes of EOS calibration.
About This Product
User Reviews
Reviews reflect personal experiences and are not medical advice. Always consult your doctor.
Manufacturer
DECATUR MEMORIAL HOSP
Source
FDA_OB · 206319
11 DESCRIPTION 11.1 Chemical Characteristics Choline C 11 Injection is a positron emitting radiopharmaceutical that is used for diagnostic purposes in conjunction with PET imaging. The active ingredient, 11 C-choline, has the molecular formula of C 4 11 CH 14 NOCl with a molecular weight of 138.63 g and has the following chemical structure: Choline C 11 Injection is provided as a ready to use sterile, pyrogen-free, clear and colorless solution. Each milliliter contains 148 – 1,225 MBq (4 – 33.1 mCi) of 11 C-choline at EOS calibration time in aqueous 0.9% sodium chloride solution. The pH of the solution is between 4.5 and 7.5. C-11 choline chloride structure 11.2 Physical Characteristics Carbon 11 is a cyclotron-produced radionuclide that decays to Boron 11 by positron emission and has a physical half life of 20.4 minutes (Table 2). Table 2: Principal Radiation Emission Data for 11 C Radiation/Emission % Per Disintegration Energy Positron (β+) 99.76 960.2 keV (Max.) Gamma (±)* 199.5 511 keV *Produced by positron annihilation The specific gamma ray constant (point source air kerma coefficient) for 11 C-choline is 5.8 R/mCi-hr at 1 cm. Selected coefficients of attenuation are listed in Table 3 as a function of lead shield thickness. For example, the use of 39 mm thickness of lead will attenuate the external radiation by a factor of about 1,000. Table 3: Radiation Attenuation of 511 keV Photons by lead (Pb) shielding Shield Thickness (Pb) mm Coefficient of Attenuation 4 0.5 8 0.25 13 0.1 26 0.01 39 0.001 52 0.0001 Table 4 lists fractions remaining at selected time intervals from the calibration time. This information may be used to correct for physical decay of the radionuclide. Table 4: Physical Decay Chart for 11 C Minutes Fraction Remaining 0* 1.000 5 0.844 10 0.712 15 0.600 20 0.507 25 0.427 30 0.360 *Calibration time